Navigate on this page
Articles
(18 st)-
DTK10Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-10 kPa
- Max. overload pressure
- 60 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK10-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-10 kPa
- Max. overload pressure
- 60 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK20Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-20 kPa
- Max. overload pressure
- 120 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK20-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-20 kPa
- Max. overload pressure
- 120 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK40Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-40 kPa
- Max. overload pressure
- 200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK40-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-40 kPa
- Max. overload pressure
- 200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK100Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-100 kPa
- Max. overload pressure
- 500 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK100-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-100 kPa
- Max. overload pressure
- 500 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK250Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-250 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK250-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-250 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK400Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-400 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.8 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK400-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-400 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.8 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK600Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-600 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK600-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-600 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK1000Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-1000 kPa
- Max. overload pressure
- 2000 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK1000-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-1000 kPa
- Max. overload pressure
- 2000 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Two wire cable, 1.5 m
-
DTK1600Differential pressure transmitter
- Power Supply
- 24 V AC +/- 15% or 18…33 V DC, 0,1 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-1600 kPa
- Max. overload pressure
- 3200 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Three wire cable, 1.5 m
-
DTK1600-420Differential pressure transmitter
- Power Supply
- 11…33 V DC, 0.5 VA
- Dimensions, external (WxHxD)
- 40x79x mm
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-1600 kPa
- Max. overload pressure
- 3200 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs %
- Cabel
- Two wire cable, 1.5 m
Specifications
Protection class | IP65 |
---|---|
Storage temperature | -15…85 °C |
Media | liquids and gases |
Pressure connection | 6 mm for copper tube |
Dynamic response time | <5 ms |
Material, housing | Stainless steel |
Material sensor | Ceramic material |
Software & documentation
Product sheet
Instructions
Accessories
DTK-NIPPEL
Nipple (R=1/8'' 27NPT) for connection of Ø 6 mm copper pipe
DTK-R