Navigate on this page
Articles
(5 st)-
MTID30H
- Sensor element
- Liquid-filled copper capillary with 200 mm protection spring
- Probe insertion length
- 200 / Ø 21 mm
- Electrical contact
- SPDT microswitch
- Switching capacity
- 15 (8) A, 24…250 V AC
- Setpoint value, temperature range
- -30...30 °C
- Step function
- 1
- Hysteresis, temperature
- 1 K
- Reset function
- Automatic
- Setpoint adjustment
- Internal
- Dimensions, external (WxHxD)
- 70x72x108 mm
-
MTID60S
- Sensor element
- Liquid-filled copper capillary with 200 mm protection spring
- Probe insertion length
- 200 / Ø 21 mm
- Electrical contact
- SPDT microswitch
- Switching capacity
- 15 (8) A, 24…250 V AC
- Setpoint value, temperature range
- 0...60 °C
- Step function
- 1
- Hysteresis, temperature
- 2...20 K
- Reset function
- Automatic
- Setpoint adjustment
- External
- Dimensions, external (WxHxD)
- 70x86x108 mm
-
MTID60-2
- Sensor element
- Liquid-filled copper capillary with 200 mm protection spring
- Probe insertion length
- 200 / Ø 21 mm
- Electrical contact
- SPDT microswitch
- Switching capacity
- 15 (8) A, 24…250 V AC
- Setpoint value, temperature range
- 0...60 °C
- Step function
- 2
- Hysteresis, temperature
- 1 K
- Step differential
- 2...5 K
- Reset function
- Automatic
- Dimensions, external (WxHxD)
- 70x86x108 mm
-
MTID60
- Sensor element
- Liquid-filled copper capillary with 200 mm protection spring
- Probe insertion length
- 200 / Ø 21 mm
- Electrical contact
- SPDT microswitch
- Switching capacity
- 15 (8) A, 24…250 V AC
- Setpoint value, temperature range
- 0...60 °C
- Step function
- 1
- Hysteresis, temperature
- 1 K
- Reset function
- Automatic
- Setpoint adjustment
- External
- Dimensions, external (WxHxD)
- 70x86x108 mm
-
MTID120HR
- Sensor element
- Liquid-filled copper capillary with 200 mm protection spring
- Probe insertion length
- 200 / Ø 21 mm
- Electrical contact
- SPDT microswitch
- Switching capacity
- 15 (8) A, 24…250 V AC
- Setpoint value, temperature range
- 50...120 °C
- Step function
- 1
- Hysteresis, temperature
- Maximum manual reset
- Reset function
- Manual
- Setpoint adjustment
- Internal
- Dimensions, external (WxHxD)
- 70x72x108 mm
Specifications
Max. probe temperature | 60 °C |
---|---|
Probe insertion length | 200 / Ø 21 mm |
Appliance class | Class I |
Protection class | IP65 |
Ambient humidity (non-condensing) | 10…90 % RH |
Storage temperature | -40…70 °C |
Storage humidity | 10...95 % RH |
Weight, incl. packaging | 0.69 kg |
Material, cover | ABS |
Material, base | PC+ABS blend (Bayblend®) |
Software & documentation
Product sheet
Instructions
Accessories
DR-25
Spiral protection bracket for capillary