Navigate on this page
Articles
(42 st)-
SSCU25-3.5-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-3.5-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-3.5-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-3.5-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-3.5-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-3.5-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 3.5 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU25-6.0-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN25
- Flow, Qp
- 6 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Media
- Water only
-
SSCU40-10-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU40-10-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU40-10-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU40-10-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU40-10-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU40-10-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN40
- Flow, Qp
- 10 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU50-15-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU50-15-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU50-15-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU50-15-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU50-15-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU50-15-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN50
- Flow, Qp
- 15 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 270 mm
- Media
- Water only
-
SSCU65-25-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU65-25-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU65-25-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU65-25-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU65-25-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU65-25-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN65
- Flow, Qp
- 25 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU80-40-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN80
- Flow, Qp
- 40 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Media
- Water only
-
SSCU100-60-CR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 360 mm
- Media
- Water only
-
SSCU100-60-CR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 360 mm
- Media
- Water only
-
SSCU100-60-CR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 360 mm
- Media
- Water only
-
SSCU100-60-HR-M
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 360 mm
- Media
- Water only
-
SSCU100-60-HR-MPI
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 360 mm
- Media
- Water only
-
SSCU100-60-HR-PO
- Power Supply
- Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
- Nominal diameter
- DN100
- Flow, Qp
- 60 m³/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 360 mm
- Media
- Water only
Specifications
Protection class | IP54 |
---|---|
Ambient humidity (non-condensing) | 5…95 % RH |
Storage temperature | 1…60 °C |
Temperature range cooling | 0...50 °C |
Temperature range heating | 0...150 °C |
Temperature resolution | 0.01 °C |
Measurement cycle, temperature | 2...60 s |
Measurement cycle, flow | 2 s |
Display | LCD, 8 digits + special characters |
Display units | MWh, kW, GJ, m 3 , m 3 /h (kWh, GJ, l , l/h, MW, MMBTU, Gcal), 3 decimal places. The unit for energy consumption can only be set while the energy consumption is ≤ 10 kWh. |
Mechanical class | Class M2 (MID: 31.03.2004 annex I) |
EMC | Class E2 (MID: 31.03.2004 annex I) |
Cable length temperature sensor | 3 m |
Diameter temperature sensor | 6 mm |
Temperature sensor installation | Indirect in a temperature sensor pocket per EN1434 |
Temperature sensor requirements, heat meter | EU (MID) identification on the temperature sensors |
Temperature sensor requirements, cooling meter | National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different |
Flow meter mounting position | Horizontal or vertical, the transducers (black housing) to the side of or under the measuring tube for cooling applications |
Flow meter, point of installation | Return flow (if forward flow installation is needed, the installation position can be changed with the main button) |
Flow meter temperature range | Heating 10…130 °C |
Measuring principle | Ultrasonic; time-of-flight |
Accuracy according to MID | Class 2 |
Software & documentation
Product sheet
Other documentation
Accessories
TH-85-1/2
Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter
TH-120-1/2
Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter
OPTO-CABLE-USB
Optocoupler with USB interface
OPTO-TOOL
Software device monitor
POWERPACK-EM
230 V power pack
POWERPACK-EM-24
24 V AC power pack
BATTERY-EM
Battery for SSU and SSCU